  Analytical Sensors


2724 / 2726 / 2726-HF / 2726-LC / 2725
2714 / 2715 / 2716 / 2717 pH & ORP Electrodes
2774 / 2776 / 2777 / 2756-WT / WT-1 / WTP / WTP-1

Feature-packed +GF+ SIGNET pH & ORP Electrodes provide unsurpassed simplicity, reliability and accuracy for a wide variety of industrial applications. Rugged CPVC construction, large reference volume and intelligent positioning of internal elements combine to extend the service-life of these dependable and highly responsive sensors. Flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating. The unique twist-lock design enables sensor connections in one easy motion. This includes the integral temperature sensor in pH electrodes, and the I.D. circuit in ORP electrodes. These contacts are used for automatic sensor recognition by +GF+ SIGNET pH/ORP Instrumentation, adding convenience and versatility to +GF+ Signet systems.
Features:
  • Durable CPVC Body
  • Twist-lock design for easy installation and maintenance
  • Flat versions resist fouling and reduce risks of breakage
  • Large reference volume and solid polymer electrolyte
         for long service life
  • pH electrodes include an integrated temperature sensor
  • Reference element positioned for maximum protection from
         process contamination
  • Symmetric arrangement of thermistor and reference elements
         optimizes temperature compensation in pH measurements
  • Designed for use with +GF+ SIGNET Pre-amplifier
  • Double 0-ring seal protects the electrical interconnection
         between sensor and pre-amplifier
  • DI option (pH) for pure water use (<100 ?S)
  • HF option (pH) extends electrode life in applications
         containing trace amounts of HF (<2%)
  • Download PDF Literature:
    Data Sheet
    Instruction Manual



    Pre-Amplifier

    Pre-amplification is required to protect the relatively weak output signal of pH & ORP electrodes from a wide variety of electromagnetic interference common in industrial environments. The +GF+ SIGNET Pre-amplifier is installed locally, at the sensing point, to maximize this protection while allowing cable extensions up to 120 m (400 ft.). The unique twist-lock design simplifies installation and maintenance by providing for the quick connection and disconnection of electrodes. And the CPVC body is virtually unbreakable for extended service-life in both submersible and in-line applications. If remote pre-amplification is necessary (e.g., tank temperature > 80? C), or if connecting to another manufacturer?s electrode, use the +GF+ SIGNET 2721 Remote Pre-amplifier.
    Features:
  • Twist-lock design allows quick connect/disconnect of sensors
  • Local pre-amplification for submersible and in-line
         installations
  • Unbreakable CPVC body
  • Designed for use with +GF+ SIGNET pH & ORP Electrodes
         to assure signal integrity up to 120 m. (400 ft.)
  • Download PDF Literature:
    Data Sheet
    Instruction Manual


    2750 and 2760 DryLoc pH/ORP Sensor Electronics and Preamplifiers

    The +GF+ SIGNET 2750 and 2760 pH/ORP Sensor Electronics and Preamplifiers, featuring Dryloc? connectors, provide a variety of functions to suit various requirements. The 2760 is a preamplifier that allows any DryLoc? pH/ORP electrode to work with most +GF+ SIGNET instruments. It can also be used as a simple connector for use with other manufacturers' instruments that do not require a preamplified signal.

    The 2750 comes with the same pre-amplified signal as the 2760, but features two different outputs: a two-wire 4 to 20mA loop output, or a digital output which allows for longer cable lengths and is compatible with the +GF+ SIGNET 8900 Multi-Parameter Controller. The 2750 devices self-configure for pH or ORP operation via automatic recognition of the electrode type. The optional EasyCal feature allows simple push-button calibration and includes an LED indicator for visual feedback.
    Features:
  • In-line integral mount and submersible installation versions
  • Automatic temperature compensation
  • Auto configuration for pH or ORP operation
  • Optional EasyCal calibration aid
  • Automatic buffer recognition
  • Junction boxes for convenient wiring
  • Compatible with 3719 pH/ORP Wet-Tap
  • Download PDF Literature:
    Data Sheet


    2754-2757 pH and ORP Electrodes

    +GF+ SIGNET 275X pH and ORP Electrodes feature a unique connector designed specifically for use with the 2750 Sensor Electronics (the robust configuration also supports the weight and torque associated with the installation and operation of integral junction boxes, and the Local EasyCal accessory). Rugged CPVC construction, large reference volume and intelligent positioning of internal elements combine to extend the service-life of these dependable and highly responsive electrodes. Flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating.
    Features:
  • Designed for use with 2750 Sensor
  • Foul-proof connector
  • Gold-plated contacts
  • Durable CPVC body
  • Self-cleaning flat versions reduce risk of glass breakage
  • Large reference volume and solid polymer electrolyte
  • Temperature sensor included in pH electrodes
  • DI option for pure water
  • HF option for pH
  • Download PDF Literature:
    Data Sheet
    Instruction Manual


    2764-2767 Differential DryLoc? pH/ORP Electrodes

    The +GF+ SIGNET 2764-2767 Differential pH and ORP Electrodes are built with the Dryloc? connector, a Ryton body and Teflon? reference junction to handle even the most extreme and harshest of chemical applications. These differential electrodes use the field-proven 3-electrode differential technique: the pH and reference electrodes are measured against a ground electrode, insuring a steady and stable signal. The key feature of the differential design is the reference electrode. The reference element is protected in a glass half-cell embedded in the reference chamber and is protected from compounds that may contain sulfides and metals. To ensure a long service life, the reference features a refillable electrolyte chamber and a replaceable equitransferant salt bridge, both easily serviced in the field. The patented porous Teflon? reference junction resists fouling, clogging and chemical attack.
    Features:
  • Differential design for stable measurements in the most
          aggressive applications
  • Water-tight DryLoc? connector with foul-proof gold contacts
  • Porous Teflon? reference junction
  • Rebuildable reference electrode
  • Solution ground
  • Temperature sensor
  • Quick temperature response
  • Easy sensor replacement using DryLoc? electrode connector
  • Download PDF Literature:
    Data Sheet

    2774-2777 Threaded DryLoc? pH/ORP Electrodes

    The +GF+ SIGNET 2774-2777 pH and ORP Electrodes feature a unique foul-proof DryLoc? connector with gold-plated contacts designed specifically for use with the +GF+ SIGNET 2750 and 2760 preamplifiers, sensor electronics, and connectors. These dependable and highly responsive electrodes feature a Teflon? double reference junction and a large reference chamber that combine to extend the service-life. Embedded positioning of the temperature element in the pH/ORP sensing tip allows the temperature response to be quick and accurate. The electrodes are offered with either flat or bulb style sensing elements. The flat versions allow sediment and particles to sweep past the measurment surface, minimizing risks of abrasion, breakage and coating. The bulb versions can be used for general-purpose applications. Due to the specially designed chambers which keep electrolytes in place, all versions can be mounted at any angle, even inverted.
    Features:
  • Durable DryLoc? connector with gold plated contacts
  • Special design allows mounting at any angle
  • Quick temperature response
  • Easy sensor replacement using DryLoc? electrode connector
  • High temperature versions available
  • Mounts into standard 3/4 inch threads
  • Download PDF Literature:
    Data Sheet

    +GF+ SIGNET 3719 pH/ORP Wet-Tap

    The +GF+ SIGNET 3719 pH/ORP Wet-Tap allows installation and removal of pH or ORP electrodes without the need for process shutdown during routine electrode maintenance and calibration. Process isolation is achieved with a double O-ring seal on a unique and compact retraction assembly; no separate valve is required. A cam-activated automatic locking mechanism, SafeLoc?, and the short stroke design help to assure operator safety.
    Features:
  • Removes electrodes from pressurized systems for routine
          service or replacement
  • Automatic process isolation upon electrode retraction - no
          separate valve required
  • Space saving 45mm short-stroke design
  • Sealed pneumatic dampening for smooth and safe operation
  • SafeLoc? Cam-activated automatic locking mechanism
  • Compatible with TwistLock and DryLoc? Electrodes for use
          with Preamplifier or 2750 pH/ORP Sensor
  • Download PDF Literature:
    Data Sheet

    2819-2823 Conductivity Sensors

    +GF+ SIGNET Conductivity/Resistivity Sensors are designed to provide versatile installation and accurate sensing across a very broad dynamic range. Coupled with +GF+ SIGNET-patented measuring circuitry a three decade range with ?2% of reading accuracy is achieved without the need for troublesome sensor platinization. Platinum RTD (PT-1000) properly located within the sensor allows optimal temperature sensing. Standard wiring allows connection without costly "patch cords".
    Features:
  • Controlled surface finish ensures accuracy and repeatability
  • Flow-through design
  • In-line or submersible mounting
  • Certified cells ?2% meets USP requirements
  • Standard process connections (3/4" NPT Polypro,
         Tri-clamp 1 - 1 1/2", 2", Opt. 1/2" NPT 316 SS)
  • 316 SS Standard Electrode
  • Alternate materials (Titanium, Hastelloy-C, Monel)
  • PTFE insulator
  • Download PDF Literature:
    Data Sheet
    Instruction Manual



    2839-2842 DryLoc? Conductivity / Resistivity Electrodes

    The 2839-2842 DryLoc? Conductivity / Resistivity Electrodes are available in four cell constants from 0.01 to 10.0, and are suitable for a wide variety of applications from high purity water quality monitoring to demineralizer regeneration. 316SS electrode surface finishes are controlled in a precision bead blasting operation to ensure measurement accuracy and repeatability, and the PEEK? insulator and process connections are injection over-molded to minimize variance between electrodes. The DryLoc? electrode connector quickly forms a robust assembly with the 2850 Conductivity / Resistivity Sensor for submersible and in-line installations.
    Features:
  • DryLoc? electrode connector for use with 2850 Conductivity
          / Resistivity Sensor Electronics
  • Controlled surface finish ensures accuracy and repeatability
  • 316SS electrodes with injection molded PEEK™ process
          connections and insulators
  • Compact electrode length for easy in-line installation
  • Replaceable insulator on Model 2842
  • Triple orifice flow-through design reduces clogging and
          bubble entrapment
  • Download PDF Literature:
    Data Sheet

    2850 DryLoc? Conductivity / Resistivity Sensor

    The 2850 DryLoc? Conductivity / Resistivity Sensors provide two-wire 4 to 20mA output without the expense of local display and other luxuries available in full-featured transmitters. Eight 4 to 20mA output ranges for each electrode cell constant, plus the ability to invert each range, are selectable by the user in the field. These sophisticated sensors also provide S3L? digital interface, another example of leading-edge tachnology from +GF+ SIGNET.
    Features:
  • S3L? Digital Interface
  • Two-wire 4 to 20mA output with many range settings
  • In-line integral mount and submersible installation versions
  • Automatic electrode cell constant recognition
  • Automatic temperature compensation
  • DryLoc? electrode connector
  • Optional EasyCal with automatic standard test solution
          recognition
  • Junction boxes for convenient wiring
  • Download PDF Literature:
    Data Sheet

    2350 Temperature Sensor

    The +GF+ SIGNET 2350 Temperature Sensor has an all PVDF body to maintain purity and outlast metal sensors in aggressive liquids eliminating the need for costly custom thermowells. Standard 3/4" NPT thread allows simple installation in any piping system. Threaded both ends allow for submersion in process vessels or for in-line applications with attachment of conduit. Digital signal allows for wiring distances between sensor and +GF+ SIGNET 3-8350 Temperature Transmitter of up to 200 ft. An integral adapter (optional) allows for integration of the sensor and transmitter into a compact assembly.
    Features:
  • Standard 3/4" NPT Process Connection
  • PT-1000 Platinum RTD sensor
  • Easy Installation
  • Threaded for In-line or submersion
  • Digital Output
  • Download PDF Literature:
    Data Sheet
    Instruction Manual


    2450 Pressure Sensors

    The 2450 Pressure Sensor has a one-piece injection molded PVDF body and ceramic diaphragm for superior compabitility in corrosive liquids. Three pressure versions allow for optimal resolution matched to your sensing needs. Solid state circuitry eliminates drift. Built-in temperature compensation provides outstanding accuracy over wide temperature ranges.
    Features:
  • S3L? or 4 to 20mA outputs
  • Standard 3/4 in. NPT process connection or 1/2 in. male union
  • One-piece injection molded PVDF body
  • Flush ceramic diaphragm
  • Easy installation
  • Three pressure ranges
  • Download PDF Literature:
    Data Sheet

    J.L. Wingert Representatives can assist you with the selection of equipment best suited to your specific needs. Contact our customer service department by e-mail at customerservice@jlwingert.com or call us Monday through Friday from 7:00 a.m. to 5:00 p.m. PST at (714) 379-5519, or fax us at (714) 379-5549.

    Send mail to the webmaster with questions or comments about this web site.
    Copyright © 2005 J.L. Wingert Company - Last modified: 11/16/11